MULTI-TECH SYSTEMS, INC. MT56DSU2 Card Type DSU/CSU (synchronous/asynchronous) Transfer Rates 56Kbps/19.2Kbps/9600bps/4800bps/2400bps Data Bus External Data Modulation DDS Protocol Topology Star/Peer-Peer [Image] CONNECTIONS Function Label Function Label RS-232 port CN1 V.35 port CN4 DC power CN2 Power switch SW1 RJ-48 line out CN3 USER CONFIGURABLE SETTINGS Setting Label Position » RTS forced high SW2/6 Off RTS normal SW2/6 On » DSR forced high SW2/7 Off DSR normal SW2/7 On » Synchronous mode SW2/8 On Asynchronous mode SW2/8 Off » Loopback test mode disabled SW2/9 On Loopback test mode enabled SW2/9 Off » Test pattern mode disabled SW2/10 On Test pattern mode enabled SW2/10 Off » Circuit assurance function disabled SW2/11 On Circuit assurance function enabled SW2/11 Off » System status function disabled SW2/12 On System status function enabled SW2/12 Off » Elastic store function disabled SW3/3 On Elastic store function enabled SW3/3 Off » Anti-streaming function disabled SW3/4 Off Anti-streaming function enabled SW3/4 On ASYNCHRONOUS MODE BIT LENGTH Setting SW3/1 SW3/2 9-bit On Off » 10-bit Off On 11-bit On On CLOCK SOURCE Setting SW2/4 SW2/5 Internal On On External Off Off » From DDS network Off On TRANSMISSION RATE Setting SW2/1 SW2/2 SW2/3 2400bps Off Off Off 4800bps Off On Off 9600bps Off Off On 19.2Kbps Off On On » 56Kbps On On On DIAGNOSTIC LED(S) LED Color Status Condition SD Red On DSU is transmitting data SD Red Off DSU is not transmitting data RD Red On DSU is receiving data RD Red Off DSU is not receiving data CD Red On Carrier signal detected CD Red Off Carrier signal not detected 56 Red On DSU connected at 56Kbps 56 Red Off DSU not connected at 56Kbps 19.2 Red On DSU connected at 19.2Kbps 19.2 Red Off DSU not connected at 19.2Kbps 96 Red On DSU connected at 9600bps 96 Red Off DSU not connected at 9600bps 48 Red On DSU connected at 4800bps 48 Red Off DSU not connected at 4800bps CTS Red On CTS signal is high CTS Red Off CTS signal is low RTS Red On RTS signal is high RTS Red Off RTS signal is low NS Red On DDS signal not detected NS Red Off DDS signal detected NS Red Blinking Errors detected in test pattern OOS Red On DDS network out-of-service condition detected OOS Red Off DDS network out-of-service condition not detected TM Red On DSU is in test mode TM Red Off DSU is not in test mode